Y.Larionova
5-th Russian Conference “Geochronometrical Isotopic Systems, their Research Methods, Geological Process Chronology” At the Institute of ore fields geology, petrography, mineralogy and chemistry of Russian Academy of Science in June 4–6 took place the 5-th Russian conference on isotopic geochronology. It was mainly dedicated to the geochronology research methodology.
5-th Russian Conference “Geochronometrical Isotopic Systems, their Research Methods, Geological Process Chronology” At the Institute of ore fields geology, petrography, mineralogy and chemistry of Russian Academy of Science in June 4–6 took place the 5-th Russian conference on isotopic geochronology. It was mainly dedicated to the geochronology research methodology.
Tags: continental crust isotopic geochronology zircon изотопная геохронология континентальная кора цирконы
Instrumentation and components
A.Bolotokov, D.Zaytsev, A.Liutzay, A.Cherbakov
Kumakhov Polycapillary Optics and Analytical Instrumentation on their Basis X-ray analysis technology is one of the main tools of current analytics. M.A.Kumakhov X-ray lens let to considerably enhance their capabilities. More then five thousand analytical instruments use Kumakhov optics.
Kumakhov Polycapillary Optics and Analytical Instrumentation on their Basis X-ray analysis technology is one of the main tools of current analytics. M.A.Kumakhov X-ray lens let to considerably enhance their capabilities. More then five thousand analytical instruments use Kumakhov optics.
Tags: kumakhov optics polycapillary optics x-ray lens оптика кумахова поликапиллярная оптика рентгеновские линзы
A.Abolin, Pierre-Francois Icart
Modern Preparative Flash Chromatography. Part I The article is dedicated to flash chromatography - a modern method of preparative liquid chromatography. The hardware of Interchim SA (France) company for the classical flash chromatography, Ultra-Performance Flash Purification and the most modern equipment: the so-called "flash crossovers".
Modern Preparative Flash Chromatography. Part I The article is dedicated to flash chromatography - a modern method of preparative liquid chromatography. The hardware of Interchim SA (France) company for the classical flash chromatography, Ultra-Performance Flash Purification and the most modern equipment: the so-called "flash crossovers".
Tags: preparative chromatography, flash chromatography, organic synthe препаративная хроматография, флеш-хроматография, органический си
M.Nehin, A.Kuznetsov , P.Chapon
Glow Discharge Spectrometer PROFILER-2 – Powerful Analytical Tool Layer-by-Layer Analysis of Materials Authors of article carried out comparison of methods of the level-by-level element analysis and presented wide opportunities of multi-purpose Glow Discharge Spectrometer PROFILER-2, HORIBA Scientific which takes a worthy place in a wide range of analytical instruments.
Glow Discharge Spectrometer PROFILER-2 – Powerful Analytical Tool Layer-by-Layer Analysis of Materials Authors of article carried out comparison of methods of the level-by-level element analysis and presented wide opportunities of multi-purpose Glow Discharge Spectrometer PROFILER-2, HORIBA Scientific which takes a worthy place in a wide range of analytical instruments.
Tags: analytical instruments glow discharge spectrometer level-by-level elemental analysis аналитические приборы спектрометр тлеющего разряда элементный послойный анализ
E.Avdiev, I.Zubov
Series AD Automatic Multichannel Aspirators The article is devoted to a most pressing challenge of creating automatic digital aspirators demand for which intensely develops in the process of implementing precise air quantitative and qualitative analysis.
Series AD Automatic Multichannel Aspirators The article is devoted to a most pressing challenge of creating automatic digital aspirators demand for which intensely develops in the process of implementing precise air quantitative and qualitative analysis.
Tags: analytical methods aspirator quantitative and qualitative analysis rotameter аналитические методы аспиратор количественный и качественный анализы ротаметр
Methodology
A.Wille, R.Proost, A.Steinbach
Trace-level Determination of Bromate in Water Quality control of drinking water is very important problem. The process of water purification may carry a risk of formation of harmful chemicals to humans, such as bromate ions. This article describes an innovative method for the trace analysis of bromates in water with optimized post-column derivatization and UV/VIS detection of the triiodide.
Trace-level Determination of Bromate in Water Quality control of drinking water is very important problem. The process of water purification may carry a risk of formation of harmful chemicals to humans, such as bromate ions. This article describes an innovative method for the trace analysis of bromates in water with optimized post-column derivatization and UV/VIS detection of the triiodide.
Tags: bromate trace-level concentration uv/vis detection бромат-ион следовая концентрация спектрофотометрическое детектирование
C.Sychev, I.Styskin
HPLC Separation of Tea and Coffee Compounds in HILIC mode HILIC HPLC mode was used to separate natural compounds of coffee (coffeyl-quinic acids) and tea (catechins). The elution orders of the mentioned substances on amino silica-gel stationary phase with use of acetonitrile-water-phosphoric acid mobile phases were also elucidated.
HPLC Separation of Tea and Coffee Compounds in HILIC mode HILIC HPLC mode was used to separate natural compounds of coffee (coffeyl-quinic acids) and tea (catechins). The elution orders of the mentioned substances on amino silica-gel stationary phase with use of acetonitrile-water-phosphoric acid mobile phases were also elucidated.
Tags: catechins гидрофильная вэжх coffeyl-quinic acids hilic natural compounds гидроксикоричные кислоты катехины природные соединения
Y.Kalambet, K.Mikhaylova, Y.Kozmin, I.Nagaev
Chromatographic Peaks Recovery by Means of Exponentially Modified Gaussian Exponentially modified Gaussian (EMG) is used extensively for chromatographic peak approximation. Authors have found a procedure of decomposing overlapping chromatographic peaks into EMG peaks with the linear optimization method. A sound way for calculating the EMG form by one of two alternative expressions and a simple method for determination of the EMG peak position were found.
Chromatographic Peaks Recovery by Means of Exponentially Modified Gaussian Exponentially modified Gaussian (EMG) is used extensively for chromatographic peak approximation. Authors have found a procedure of decomposing overlapping chromatographic peaks into EMG peaks with the linear optimization method. A sound way for calculating the EMG form by one of two alternative expressions and a simple method for determination of the EMG peak position were found.