Estimation of the isotopic composition of the fuel is an important task for the nuclear industry. Several basic techniques are known for determining the isotopic composition of heavy elements, such as uranium, both more accurate and longlasting, and express. For production with a large number of samples, the method of total complete evaporation is optimal, providing a high degree of automation and acceptable accuracy of analysis. Total Full evaporation also allows to reduce the qualification level in sample preparation, thereby reducing errors in the results. In this work, standard samples of the composition NBS U010, NBL U030a, and NBL U050 were tested by the method of complete evaporation using a Phoenix thermal ionization mass spectrometer (Isotopx, UK). Statistical processing of the results of a series of experiments showed that, in comparison with others, the total complete evaporation method better meets the accuracy requirements for determining the 235 U/ 238U isotopic ratio and is consistent with published data.

sitemap
Наш сайт использует cookies. Продолжая просмотр, вы даёте согласие на обработку персональных данных и соглашаетесь с нашей Политикой Конфиденциальности
Согласен
Search:

Sign in
Analytics
Editorial policy
Articles annotations
For authors
For reviewers
Publisher
Contact us
TECHNOSPHERA
TS_pub
technospheramag
technospheramag
ТЕХНОСФЕРА_РИЦ
© 2001-2025
РИЦ Техносфера
Все права защищены
Тел. +7 (495) 234-0110
Оферта

Яндекс.Метрика
R&W
 
 
Sign in:

Your e-mail:
Password:
 
Create your account
Forgot your password?
FOR AUTHORS:

Instruction to authors
FOR REVIEWERS:

Книги по аналитике
Магеррамов А.М., Байрамов М.Р.
Другие серии книг:
Мир химии
Библиотека Института стратегий развития
Мир квантовых технологий
Мир математики
Мир физики и техники
Мир биологии и медицины
Мир наук о Земле
Мир материалов и технологий
Мир электроники
Мир программирования
Мир связи
Мир строительства
Мир цифровой обработки
Мир экономики
Мир дизайна
Мир увлечений
Мир робототехники и мехатроники
Для кофейников
Мир радиоэлектроники
Библиотечка «КВАНТ»
Умный дом
Мировые бренды
Вне серий
Библиотека климатехника
Мир транспорта
Мир фотоники
Мир станкостроения
Мир метрологии
Мир энергетики
Книги, изданные при поддержке РФФИ
Issue #3/2020
Z. Palacz
Measurement Evaluation of the Isotopic Composition Uranium Standards by Total Evaporation Using a Thermal Ionization Mass Spectrometer
Estimation of the isotopic composition of the fuel is an important task for the nuclear industry. Several basic techniques are known for determining the isotopic composition of heavy elements, such as uranium, both more accurate and longlasting, and express. For production with a large number of samples, the method of total complete evaporation is optimal, providing a high degree of automation and acceptable accuracy of analysis. Total Full evaporation also allows to reduce the qualification level in sample preparation, thereby reducing errors in the results. In this work, standard samples of the composition NBS U010, NBL U030a, and NBL U050 were tested by the method of complete evaporation using a Phoenix thermal ionization mass spectrometer (Isotopx, UK). Statistical processing of the results of a series of experiments showed that, in comparison with others, the total complete evaporation method better meets the accuracy requirements for determining the 235 U/ 238U isotopic ratio and is consistent with published data.
Measurement Evaluation of the Isotopic Composition Uranium Standards by Total Evaporation Using a Thermal Ionization Mass Spectrometer
 
 Readers feedback
Разработка: студия Green Art